Agitek Service
Agitek instrument maintenance center

NToll-free Hotline400-8765512

Hello, welcome to Xi 'an Agitek Service!      Instrument Maintenance | Rental/Used Instruments | I Need Repairs | Contact us | Service Centre | Chinese

Current location:Home>Instrument>Network Analyzer

    85106C Vector Network Analyzer Repair

    85106C Vector Network Analyzer Repair

      85106C vector network maintenance repairable faults:

      1. 85106C vector network analyzer maintenance power failure: can not start normally

      2. 85106C vector network maintenance repairable input terminal failure: the port does not respond normally; no output; no input; abnormal signal

      3. 85106C vector network maintenance repairable test analysis failure: abnormal test result; calibration failure; out of tolerance

      4. 85106C vector network maintenance repairable display failure: garbled characters; black screen

      5. 85106C vector network maintenance repairable button failure: no response to the button; no response to the adjustment knob

      6. 85106C vector network maintenance can be repaired

      Interface failure: does not recognize the storage medium; cannot connect to the control system

      7. 85106C vector network maintenance can repair other use problems, etc.

      Two, 85106C vector network maintenance corner:


    85106C Vector Network Analyzer Repair

      Main technical indicators of 85106C vector network maintenance

      85106C mmWave network analyzer subsystem, 33 GHz to 110 GHz

      Frequency range from 45 MHz to 110 GHz (with options)

      Real-time error correction measurements

      0.001 dB, 0.01°, 0.01 ns measurement resolution

      Optional time domain and pulsed RF measurement capabilities

      85106C vector network maintenance procedures:

      Provide testing and quote after testing;

      If the user agrees to the maintenance, the maintenance will be started after the agreement is confirmed;

      If the user disagrees, return to the instrument.

      Agitek vector network maintenance advantages: short maintenance cycle, low price, and provide warranty services;

      Quality Assurance: After the repair, it is qualified by the measurement unit, and a "Measurement Certificate" is issued.


    85106C Vector Network Analyzer Repair


      85106C Vector Network Repair Repairable Model:

      8560 series:

      8560E 、8560E、 8561E 、8561EC、 8562E 、8562EC、 8563E、 8563EC 、8564E、 8564EC、 8565E、 8565EC、 8566B、 8567A、8568B ,and other Agilent/Keysight series have expired warranty period.

      About us:

      Xi'an Agitek Maintenance Center was established in 2008, specializing in the maintenance and technical support of various test and measurement instruments and test systems, especially good at vector network analyzer maintenance, vector network maintenance, and has the technical ability to perform chip-level maintenance of high-end instruments at home and abroad . Since its establishment, it has closely followed the pulse of instrument technology development, closely followed the development trend of electronic devices and PCB technology, and has always maintained leading maintenance technology and capabilities. After years of accumulation, it has formed dozens of imported and domestic brands, various types of testing and measuring instruments maintenance capabilities.

      Contact details:

      Xi'an Agitek Instrument Repair Center

      Company address: C608, Zhicheng Business, No. 17, Gaoxin 4th Road, High-tech Zone, Xi'an City

      Company website:www.agitekservice.com