Agitek Service
Agitek instrument maintenance center

NToll-free Hotline400-8765512

Hello, welcome to Xi 'an Agitek Service!      Instrument Maintenance | Rental/Used Instruments | I Need Repairs | Contact us | Service Centre | Chinese

Current location:Home>Maintenance service>Technical articles

How to speed up the startup of spectrum analyzer?

Time:2022-11-30             Xi'an Agitek spectrometer maintenance center    23861

  Many people are not very clear about how to speed up the startup of the spectrum analyzer. The following is an instrument maintenance engineer from Aetna Maintenance. He will show you how to speed up the startup of the spectrum analyzer. I believe that after reading this article, you can help you and avoid detours!  

  According to the industry data compiled by Xi'an agitekservice Spectrum Analyzer Maintenance Center, in order to meet the increasing demand for signal analysis applications in the market, most modern spectrum analyzers currently use Windows architecture and operating system. Because the spectrum analyzer under Windows platform has a better human-computer interaction interface and is more mature, as well as multi task working ability and good scalability, it is widely accepted by the public!

  But while we enjoy the advantages of Windows operating system, it also brings us some inconvenience more or less. Many users will feel that the spectrum analyzer of the current Windows system is slow to boot, so what is the reason? The editor of agitekservice Spectrum Analyzer Maintenance Center will tell you.

  In fact, it's very simple. Just like the PC computers we use everyday, the slow boot speed is mainly caused by too many startup items loaded. Most people can use some tools to optimize the startup items of their PCs to help improve the startup speed. For the same spectrometer, you can also optimize the startup speed by configuring the startup items.

  The small editor of agitekservice Spectrum Analyzer Maintenance Center takes Keysight (formerly Agilent) X series spectrum analyzer as an example to explain that the instrument needs to start the Windows system first after startup, and then we run the firmware "LaunchXSA. exe" of the spectrum analyzer. Because the Windows operating system of the spectrum analyzer has been optimized for the second time, there are few startup items and the speed is fast. Then the instrument will automatically start its firmware "LaunchXSA. exe". When starting the firmware, it will preload various application options installed by the spectrometer, such as WC option, Phase Noise option, etc. If the user has not optimized and installed many application options, the startup speed of the instrument will be greatly affected. In fact, most users only use one or at most several specific measurement options at a certain time. In this case, it is unnecessary to load all the options at the same time.

  The small editor of agitekservice Spectrum Analyzer Maintenance Center once again reminds you that we can optimize the startup items of the spectrum analyzer through the following two steps to directly accelerate the startup process as follows:

  Step 1: We just need to press "System - Power On – Power On Application" when the spectrometer is working, and then select our default startup option, which should be the first option you use every time you turn on.

  Step 2: When the spectrometer is working, we press "System - Power On – Configure Applications", and then select the most commonly used test options in the following interface as the startup items.

  Through the above two steps of optimization, I believe that your spectrometer can be significantly faster! I hope the above method of how to speed up the startup of the spectrum analyzer will help a wide range of instrument enthusiasts. If you find a fault with the spectrometer, as an Aetna maintenance engineer, it is recommended that you find a professional person to repair it, otherwise improper operation may lead to more serious maintenance faults of the spectrometer. Wuhan agitekservice Testing Equipment Maintenance Co., Ltd., as a professional instrument maintenance company, has been deeply involved in the spectrum instrument maintenance industry for 14 years, not limited to oscilloscope maintenance, spectrum instrument maintenance, network analyzer maintenance, power supply maintenance, thermal imager maintenance, signal source maintenance, power amplifier maintenance, etc., to help you solve any instrument maintenance problems, please feel free to consult!

  Contact information of Wuhan agitekservice Instrument Rental and Maintenance Center:

  Tel.: 17037027802

  Company website: http://www.agitekservice-wh.com/