R&S oscilloscope RTE1204 maintenance trouble? What should I do if the R&S oscilloscope RTE1204 fails? Have you encountered the R&S oscilloscope RTE1204 out of tolerance?
I believe that friends who have been in the electrical measurement industry for a long time know that R&S oscilloscope RTE1204 is a common fault, but Rohde & Schwarz RTE1204 is an imported high-end brand oscilloscope. Most people do not recommend disassembling and repairing it by themselves, because it is all past and present. Parts, slightly mishandled, can lead to other more serious failures of the R&S oscilloscope RTE1204. So, what should we do at this time? In order not to affect other work, the editor of the Agitek R&S oscilloscope repair center recommends that you come to Agitek for repair, which is a professional electrical measurement instrument repair center. Next, please follow the editor of Agitek R&S oscilloscope repair center to see the following case of R&S oscilloscope RTE1204 repair, I hope it can help you!
Instrument: R&S Oscilloscope RTE1204
Fault: out of tolerance
R&S oscilloscope RTE1204 repair process:
1. Detection: The logic unit of the acquisition board is damaged; the baselines of 4 channels are unstable after booting, and the ADC unit of the acquisition board is damaged
2. Maintenance: replace the logic unit component of the acquisition board, replace the ADC unit component of the acquisition board, adjust the testing instrument
The above is the case of out-of-tolerance maintenance of this R&S oscilloscope RTE1204 introduced by the editor of Xi'an Agitek R&S Oscilloscope Repair Center. So how do we maintain our oscilloscope on a daily basis to reduce the frequency of its failures? You can listen to the suggestions of the editor of Xi'an Agitek R&S Oscilloscope Repair Center!
1. The oscilloscope should be kept dry and clean during long-term use;
2. Vibration and shock should be prevented when using the oscilloscope;
3. After using the oscilloscope, turn off the power supply and remove the leads to reduce accidental accidents;
4. When the oscilloscope is not used, add a cover to prevent the intrusion of dust, so as to avoid the accumulation of dust and cause high-voltage arcing or even damage.
After listening to the Xiaobian's advice on repairing the Agitek R&S oscilloscope in Xi'an, everyone has learned it? I believe that according to the Xiaobian's advice, your instrument will not fail frequently! If you also have an R&S oscilloscope in need of repair, and details about the maintenance case of the Agilent Pulse Function Arbitrary Generator 81160A, you can always come to Agitek for maintenance, or you can continue to visit the Agitek maintenance website!
Xi'an Agitek Test Equipment Maintenance Center was established in 2008, specializing in the maintenance and technical support services of various test and measurement instruments and systems, and has always maintained and continuously expanded its leading maintenance technology and capabilities. The technical capability of high-end instruments for chip-level repairs. Relying on sophisticated maintenance equipment, excellent maintenance technology, reasonable maintenance price, efficient maintenance cycle and perfect after-sales service, it breaks the monopoly of the original factory, saves maintenance costs for customers and shortens the maintenance cycle.
Contact Agitek Service
Xi'an Agitek RTE1204 Repair Center
Company address: C608, Zhicheng Business, No. 17, Gaoxin Fourth Road, High-tech Zone, Xi'an City
company website:www.agitekservice.com